GacoFlex LM-60H is used on horizontal surfaces in a between slab or below grade configuration. Application is by notched trowel or squeegee in one coat or sprayed, if thinned, in two coats. The membrane is covered with a protection course and a wearing course of concrete, blacktop or pavers.
GacoFlex LM-60V is thixotropic in consistency and will cling to vertical surfaces without run-off at normal application rate. It may be applied with a trowel in one coat application or sprayed, if thinned in two coats.
When working with Part B, avoid contact with skin and eyes. If contact occurs, wash skin with water or alcohol; flush eyes immediately with large quantities of water and get medical attention. Do not smoke during mixing, application, or in the immediate area if thinners are used until all vapors have disappeared.
Acceptable Manufacturers:
Gaco Western
Liquid Applied Membrane: GacoFlex LM-60 having the following physical properties:
| Property | Value | Test Method |
| Tensile Strength | 240 ± 10 psi (1.65 ± .07 MPa) | ASTM D-412 |
| Elongation | 300% ± 20 | ASTM D-412 |
| Tear Resistance | 30 pli (5.4 kg(f) / cm) | ASTM D-624 |
| Hardness | 50 Shore A min @70°F (21°C) | ASTM D-2240 |
| Water Vapor Permeability | 0.02 Perm Inches | ASTM E-96 |
| Procedure BW 100% R.H. Difference |
||
| Solids by Volume | 100 % |
Alternate Concrete Primer Sealer. GacoFlex E-5481 two component 100% solids Epoxy concrete primer/sealer.
Unacceptable Grades: APA C-D EXT, APA C-C EXT, Exposure 1 markings, oriented strand board (OSB), waferboard and Lauan or Mahogany plywood are NOT suitable substrates for liquid-applied coating systems. This is due to poor dimensional stability, weak glue lines which allow buckling or lifting of the top ply, and excessive splintered, leafed and raised surface grain.
Refer to General Instruction GW-2-3 for complete information on the installation and fastening of plywood.
Consideration should be given to the application of the Gaco Western primer-sealer system when waterproofing exterior concrete decks that will experience solar heating during application. A phenomenon known as concrete outgassing may occur which causes blisters and pinholes in the applied coating. The use of the primer-sealer system is the best method known for prevention of blisters and pinholes.